The STC-CLC83A is a full featured, cost effective XGA progressive scan digital Camera Link® cube camera with 1/3" CCD with Color. Featuring a full frame 30fps XGA output, partial scanning, triggering, and reset capabilities.
Features:
Applications:
Image Sensor | 1/3" interline XGA colorprogressive CCD: ICX204AK |
Total picture elements | 1077 (H) x 788 (V) |
Effective picture elements | 1034 (H) x 779 (V), XGA: 1024 (H) x 768 (V) |
Chip size | μm5.8 (H) x 4.92 (V) mm |
Cell size | 4.65 (H) x 4.65 (V) μm |
Scanning system | Progressive |
Scanning method | Full scanning, Partial full scanning, 1/2 partial scanning, 1/4 partial scanning, Variable partial scanning |
Vertical frequency (Frame rate) | 29.59 Hz |
Horizontal frequency | 23.23 kHz |
Pixel frequency | 29.5 MHz |
S/N ratio (standard deviation) | <= 10 Digit (Gain 0 dB) |
Minimum scene illumination | 2 Lux at F1.4 |
Sync. System | Internal / External |
Video output | Digital 8 or 10 bit Camera Link (Base configuration) |
Tap | 1 Tap |
Shutter Speed | OFF, 1/2 to 1/100,000 sec. (Variable at every H and clock) |
Gain | 0 to 27 dB |
Gamma | 1.0 |
Input voltage | DC12V ± 10% |
Consumption | Less than 1.8 W |
Trigger mode | Edge preset trigger (V-reset, Non-reset) Pulse width trigger (V-reset, Non-reset) |
Communication | RS232 via Camera Link connector |
Dimensions | 28 (W) x 28 (H) x 46.5 (D) mm including lens mount and the connector |
Optical filter | No IR cut filter |
Optical center accuracy | Positional accuracy in H and V directions: +/- 0.31 mm Rotational accuracy of H and V:+/- 2.1 deg. |
Case | Front, base and rear: Aluminum die cast (ADC12)Cover: Steel sheet covered with zinc |
CaseTripod | Polycarbonate ABS |
Lens mount | C Mount |
Interface connector | HR10A-7R-6PB (Hirose) or equivalent |
Tripod | Tripod can be attached to 4 plates(4 screws on the bottom plate, 3 screws on the other 3 plates) |
Operational Temp | Temperature: -5 to 50 deg. C, RH: 0 to 85% (No condensation) |
Storage Temp | Temperature: -30 to 65 deg. C, RH: 0 to 90% (No condensation) |
Vibration | 20Hz to 200Hz to 20Hz (5min./cycle), acceleration 10G, 3 directions 30 min. each |
Shock | Acceleration 70G, half amplitude 6ms, 3 directions 3times each |
Standard compliancy | EMS: EN61000-6-2, EMI: EN55011 (Class B) |
RoHS | RoHS compliance |